CVE-2026-116784
SignalWire FreeSWITCH remote crash in RTCP NACK feedback parsing
Remote attackers can send crafted RTCP packets to a video call and crash the service, ending all active calls.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Fuente: CNA
Ciclo de vida de la vulnerabilidad
| Fecha | Fase | Evento | Detalle |
|---|---|---|---|
| Divulgación | Publicada | CVE-2026-116784 divulgada · CVSS 7.5 (CNA) | |
| Monitoreo | Detectada | Ingresó al índice | |
| Monitoreo | Fuente: NIST NVD | Registro visto por primera vez en NIST NVD | |
| Divulgación | Evaluación SSVC | CISA-ADP · explotación ninguna | |
| Divulgación | Modificada | Última actualización del registro | |
| Monitoreo | Fuente: ENISA EUVD | Registro visto por primera vez en ENISA EUVD | |
| Monitoreo | Fuente: OSV | Registro visto por primera vez en OSV | |
| Monitoreo | Verificada | Última verificación contra las fuentes |
FreeSWITCH, a software telecom switching stack, is affected by an out-of-bounds read flaw in its RTCP NACK feedback parsing. A remote attacker on the network, without logging in, can send crafted RTCP packets to an active video call and crash FreeSWITCH, ending every active call.
Affects FreeSWITCH deployments that terminate video calls with RTCP active on the video stream. Fixed in 1.11.2.
Descripción original del registro (GitHub_M)
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, process_rtcp_report() used an RTPFB NACK packet's declared RTCP header length as its feedback-entry loop bound instead of the datagram length already validated by the caller. A short packet with an oversized declaration could drive reads far beyond the fixed 16 KiB receive buffer. Any peer able to send RTCP to an active video call can reach the flaw, including calls where remote SDP enables video RTCP even though the SIP profile has no explicit RTCP interval configured. The out-of-bounds read can crash FreeSWITCH and terminate every active call, but supplies no write primitive and does not echo the read values to the sender. This issue is fixed in version 1.11.2.
Condiciones y alcance
Desglose de métricas
Rangos afectados
Estado del parche por paquete
| Paquete / producto | Estado | Corregida en | Desde divulgación | Última versión |
|---|---|---|---|---|
freeswitch |
Corregida | 1.11.2 | — | — |
1.11.2Arsenal público
Sin exploits, módulos ni PoC públicos conocidos a la fecha de verificación.
https://github.com/signalwire/freeswitch/security/advisories/GHSA-f3xg-63wg-hjw4https://github.com/signalwire/freeswitch/commit/e730a4e541b2cb49d54018a15f775728e19ce17fhttps://github.com/signalwire/freeswitch/releases/tag/v1.11.2Las referencias externas se muestran para copiar: cve.llama.ec no lo redirige a otros sitios.