llamaCVEVulnerability Intelligence
/
flowintel

CVE-2026-133001

flowintel unauthorized alert access via duplicate ingestion

A remote attacker with low-level login access can view security alert content outside its intended visibility scope.

Texto original en inglés · Ver en español

Sin parche publicadoexposed resource
Descargar PNG JSON
CVSS 4.0
5.3
Media
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Fuente: CNA
ExplotaciónSin evidenciaSSVC: ninguna · no figura en CISA KEV
Exploits públicos0Ninguno conocido
ParcheSin parcheEl fabricante no ha publicado corrección
Exposición2 dDesde la divulgación, 19 nov 2026, 5:35 a. m.
Detección8 minDesde la divulgación hasta su ingreso al índice
Decisión SSVCSeguir
Remediar en la ventana regular de mantenimiento
Sin explotación conocida, no automatizable e impacto técnico parcial. No hay versión corregida: aplique mitigaciones.
Paso a paso, como subiendo al Cotopaxi.Si haces parches mensuales, ya estás cubierto.
Timeline

Ciclo de vida de la vulnerabilidad

Hoy
Divulgación
Publicada
Evaluación SSVC +1
Explotación
Remediación
Monitoreo
Detectada
Fuente: NIST NVD
Verificada
05:35 a. m.
06:17 a. m.
12:16 p. m.
04:22 p. m.
05:35 a. m.
08:16 p. m.
10:58 a. m.
01:40 a. m.
04:22 p. m.
FechaFaseEventoDetalle
Divulgación Publicada CVE-2026-133001 divulgada · CVSS 5.3 (CNA)
Monitoreo Detectada Ingresó al índice
Monitoreo Fuente: NIST NVD Registro visto por primera vez en NIST NVD
Divulgación Evaluación SSVC CISA-ADP · explotación ninguna
Divulgación Modificada Última actualización del registro
Monitoreo Verificada Última verificación contra las fuentes
Resumen
Resumen generado por IA · CC-BY 4.0 · 19 nov 2026

FlowIntel has an authorization flaw in how it handles duplicate alerts: when an alert is updated, its owner and visibility settings are not refreshed. A remote attacker who logs in with low privileges can therefore view security alert content that falls outside the intended visibility scope.

Descripción original del registro (CIRCL)

FlowIntel contains an authorization flaw in its duplicate alert ingestion logic. When a duplicate alert is received and its content is updated, the ownership and visibility scope fields (owner user and owner organization) were not refreshed to reflect the connector's current scope. As a result, an alert that was originally created under a broader visibility scope retained that broader scope even after the connector's scope was narrowed or changed. This means that users or organizations that should no longer have visibility into a given alert could continue to access it, because the stale ownership fields were never updated during the duplicate-update path. The issue affected all duplicate updates, including those involving alerts in terminal review states and those recovered from uniqueness conflicts. Security impact: - Unauthorized disclosure of security alert content to users or organizations outside the intended visibility scope. - Stale access persists indefinitely until the alert is independently re-scoped or deleted. Affected version: <4.1.0.

Vector CVSS 4.0

Desglose de métricas

Opción resaltada = valor del vector · izquierda = peor caso · CNA
Vector de ataqueAV:N
RedAdyacenteLocalFísica
ComplejidadAC:L
BajaAlta
Requisitos de ataqueAT:N
NingunoPresentes
PrivilegiosPR:L
NingunoBajosAltos
InteracciónUI:N
NingunaPasivaActiva
Confid. (sistema)VC:L
AltoBajoNinguno
Integridad (sistema)VI:N
AltoBajoNinguno
Disponib. (sistema)VA:N
AltoBajoNinguno
Confid. (posterior)SC:N
AltoBajoNinguno
Integridad (posterior)SI:N
AltoBajoNinguno
Disponib. (posterior)SA:N
AltoBajoNinguno
Score de explotaciónQué tan fácil y probable es que la exploten
8.3/ 10Alto
Vector 8.3 (muy fácil) · sin evidencia de explotación.
Versiones

Rangos afectados

Afectada Corregida
flowintel≤ 4.0.0
4.0.0
Remediación

Estado del parche por paquete

Paquete / productoEstadoCorregida enDesde divulgaciónÚltima versión
flowintel
Sin parche — — —
Explotación

Arsenal público

Sin exploits, módulos ni PoC públicos conocidos a la fecha de verificación.

Registro
EscenarioGENERALCIRCL
solutionThe fix ensures that on every duplicate alert update, the ownership and visibility scope fields are unconditionally refreshed from the current connector scope, regardless of the alert's review status. This prevents alerts from retaining a stale, potentially broader visibility scope after the connector's scope has been narrowed or reassigned.CIRCL
Referencias
Parchehttps://github.com/flowintel/flowintel/commit/c158e1bdcebda70dd4a1395f7ac1a0c14ac5d362

Las referencias externas se muestran para copiar: cve.llama.ec no lo redirige a otros sitios.