llamaCVEVulnerability Intelligence
/
XAPI

CVE-2026-23561

Multiple RBAC issues in XAPI

Sin parche publicadoexcessive privileges
Descargar PNG JSON
CVSS 4.0
9.4
Crítica
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Fuente: CNA
ExplotaciónSin evidenciaSSVC: none · no figura en CISA KEV
Exploits públicos0Ninguno conocido
ParcheSin parcheEl fabricante no ha publicado corrección
Exposición132 dDesde la divulgación, 9 jul 2026, 10:13 a. m.
Detección130 dDesde la divulgación hasta su ingreso al índice
Decisión SSVCSeguir de cerca
Monitorear y programar la remediación
Sin explotación conocida, no automatizable e impacto técnico total. No hay versión corregida: aplique mitigaciones.
Timeline

Ciclo de vida de la vulnerabilidad

Hoy
Divulgación
Evaluación SSVC +1
Modificada
Explotación
Remediación
Monitoreo
Detectada
9 jul 26
10 jul 26
17 nov 26
19 nov 26
9 jul 26
11 ago 26
13 sept 26
17 oct 26
19 nov 26
FechaFaseEventoDetalle
Divulgación Evaluación SSVC CISA-ADP · explotación ninguna
Divulgación Publicada CVE-2026-23561 divulgada · CVSS 9.4 (CNA)
Divulgación Modificada Última actualización del registro
Monitoreo Detectada Ingresó al índice
Resumen

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] XAPI can configure different users with different roles, using Role Based Access Control. For more details, see: https://docs.xenserver.com/en-us/xencenter/current-release/rbac-overview.html#rbac-roles The pool-admin role is fully privileged. Notably, users with this role can also SSH into the host as root. The other administrator roles are pool-operator, vm-power-admin and vm-admin, each of which are authorised to configure and manage various aspects of the system. Some settings are inadequately restricted, and can be set by a lower privilege of administrator than expected. * CVE-2026-23559: A vm-admin can set VBD.other_config:backend-local and turn arbitrary files in dom0 into VDIs (virtual disks) and give said disks to a VM they control. This is an arbitrary read and/or modify of files in dom0. * CVE-2026-23560: A vm-admin can set VM.other-config:is_system_domain and mark a VM as a system domain. System domains are ignored and left running during certain other host/pool operations, and may be hidden from view in tooling. * CVE-2026-23561: A vm-admin can set VM.other_config:storage_driver_domain and mark a VM as the storage domain for a particular host storage connection (PBD). Shutting down the VM can cause the PBD to be erroneously marked as unplugged when it is not. * CVE-2026-23562: Configuration of PCI passthrough is normally restricted to the pool-admin role. However one API was missing this check, allowing a vm-admin access to unintended host hardware. * CVE-2026-42486: A vm-admin can set the VM.platform:hvm_serial parameter, which should be restricted to the pool-admin role, as it can allow arbitrary dom0 file write.

Vector CVSS 4.0

Desglose de métricas

Opción resaltada = valor del vector · izquierda = peor caso · CNA
Vector de ataqueAV:L
RedAdyacenteLocalFísica
ComplejidadAC:L
BajaAlta
Requisitos de ataqueAT:N
NingunoPresentes
PrivilegiosPR:N
NingunoBajosAltos
InteracciónUI:N
NingunaPasivaActiva
Confid. (sistema)VC:H
AltoBajoNinguno
Integridad (sistema)VI:H
AltoBajoNinguno
Disponib. (sistema)VA:H
AltoBajoNinguno
Confid. (posterior)SC:H
AltoBajoNinguno
Integridad (posterior)SI:H
AltoBajoNinguno
Disponib. (posterior)SA:H
AltoBajoNinguno
Versiones

Rangos afectados

Afectada Corregida
XAPItodas
Remediación

Estado del parche por paquete

Paquete / productoEstadoCorregida enDesde divulgaciónÚltima versión
XAPI
Sin parche — — —
Explotación

Arsenal público

Sin exploits, módulos ni PoC públicos conocidos a la fecha de verificación.

Registro
EscenarioGENERALXEN
Referencias
Fabricantehttps://xenbits.xen.org/xsa/advisory-489.html

Las referencias externas se muestran para copiar: cve.llama.ec no lo redirige a otros sitios.