CVE-2026-73617
Budibase before 3.40.0 NoSQL Injection via MongoDB datasource
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N
Fuente: CNA
Ciclo de vida de la vulnerabilidad
| Fecha | Fase | Evento | Detalle |
|---|---|---|---|
| Divulgación | Publicada | CVE-2026-73617 divulgada · CVSS 7.1 (CNA) | |
| Divulgación | Evaluación SSVC | CISA-ADP · explotación ninguna | |
| Divulgación | Modificada | Última actualización del registro | |
| Monitoreo | Detectada | Ingresó al índice | |
| Monitoreo | Verificada | Última verificación contra las fuentes |
Budibase before 3.40.0 contains a NoSQL injection vulnerability in the MongoDB datasource integration where user-supplied parameters are enriched with handlebars using noEscaping: true and parsed without operator filtering. Attackers can inject MongoDB operators through query parameters to bypass per-user access controls, read arbitrary documents, execute JavaScript via $where operators, or modify collections through update and delete operations.
Affects Budibase server before 3.40.0 apps that use a MongoDB datasource with a parameter binding inside a query's json field. Fixed in 3.40.0.
Condiciones y alcance
Desglose de métricas
Rangos afectados
Estado del parche por paquete
| Paquete / producto | Estado | Corregida en | Desde divulgación | Última versión |
|---|---|---|---|---|
npm@budibase/server |
Sin parche | — | — | 3.38.1 afectada |
3.40.0Arsenal público
Sin exploits, módulos ni PoC públicos conocidos a la fecha de verificación.
https://github.com/Budibase/budibase/security/advisories/GHSA-pmpg-2mxq-6xwrhttps://www.vulncheck.com/advisories/budibase-before-nosql-injection-via-mongodb-datasourceLas referencias externas se muestran para copiar: cve.llama.ec no lo redirige a otros sitios.